Overcurrent Protection NEC Article 240 and Beyond

Limba: 
english
Tip copertă: 
Greu
Număr de pagini: 
100
An overcurrent is caused by a short-circuit, ground-fault, or an overload.A short-circuit may be hundreds or even thousands of times above the normal operating current. This type of fault may be an ar ...Descriere completă
580,00 RON

Informații detaliate

Mai multe informatii
ISBN9788770226219
AutorBierals Gregory P.
EdituraRiver Publ
Limbaenglish
Tip copertăPevná vazba
Anul publicării2021
Număr de pagini100

Descrierea cărții

An overcurrent is caused by a short-circuit, ground-fault, or an overload.

A short-circuit may be hundreds or even thousands of times above the normal operating current. This type of fault may be an arcing fault between ungrounded conductors or between an ungrounded conductor and a grounded (usually, a neutral) conductor, a line-to-line arcing fault may produce a current of 74% of a 3-phase bolted fault. A line-to-neutral arcing fault will be somewhat less.

A line-to-line bolted fault, the equivalent, of the conductors bolted together, may be up to 100% of the available short-circuit current.

A line-to-neutral bolted fault may be in excess of 100% of the 3-phase bolted fault at the source, but considerably less downstream.

A ground-fault, that is, the equivalent of a connection between an ungrounded conductor and the equipment grounding system, will produce a current that may be 38% or higher of the 3-phase bolted fault current. These types of faults are typically arcing faults which normally are intermittent in nature. That is, they strike and restrike over time and may produce a short-circuit fault due to insulation damage.

Once again, a line-to-equipment ground fault near the source may produce a fault current of over 100% of the 3-phase bolted fault, but considerably less downstream.

An overload typically ranges from one to six times the normal current, and are normally caused by motor starting currents or transformer magnetizing currents. These conditions are of such short duration that the circuit components are not damaged.

This book has a detailed analysis of these types of faults, along with explanations and examples of the various types of overcurrent protective devices to assure proper protection.

This volume has extensive information on the application of overcurrent protection for conductors and equipment. The reader will be able to calculate fault currents as well as establishing the short-circuit withstand rating of conductor insulation and to determine the appropriate type of overcurrent devices based on circuit conditions.

In addition, determining ground-fault currents for the purpose of selecting the proper size of equipment grounding conductors to establish an effective ground-fault current path is discussed in detail.

Readership - Anyone involved with the design of overcurrent protection for electrical distribution systems from the system source to the electrical utilization equipment. The emphasis is placed on the design of the overcurrent protection for specific installations to assure proper protection for the circuit components regardless of the type of fault encountered.

 

  1. velký výběr

    O SELECȚIE URIAȘĂ

    Peste 4 milioane de cărți în engleză la prețuri avantajoase.

  2. poštovné zdarma

    LIVRARE GRATUITĂ

    Livrare gratuită la comenzi de peste 300 Lei (Packeta.ro)

  3. skvělé ceny

    PREȚURI AVANTAJOASE

    Încercăm să păstrăm prețurile cărților cât mai mici și întotdeauna sub prețul recomandat de editură.

  4. online podpora

    PROGRAMUL MAGAZIN DE ÎNCREDERE

    Magazinul nostru a devenit un “Magazin de încredere“ pe baza recenziilor oferite de către clienții noștri reali.

  5. osobní přístup

    ABORDARE PERSONALĂ

    Cel mai important pentru noi este satisfacția Dvs. Vindem cărți deoarece le iubim. Nu suntem giganți transnaționali, ci o companie onestă din Republica Cehă. În plus, cele mai bune cărți au recenzii în blogul nostru.